Inspections

CTI technicians perform visual inspections on condensers and heat exchangers. The techniques include three-ball micrometer measurements and a rigid borescope.

The 3-ball micrometer inspection typically consists of tube I.D. readings taken at the various depths into the tubes. This will determine the extent and depth of erosion, and the necessary dimensions required for the CTI Shield and Liner.

Coatings

CTI applies 100% solid epoxy coatings formulated to suit specific job conditions, including:

  • Abrasion
  • Erosions/Corrosion
  • Galvanic action

Re-Tubing

In the case that one of CTI’s patented restoration systems cannot solve your problem, heat exchangers can be re-tubed In-situ or in one of our fully equipped workshops.

Tube Cleaners

  • CTI Nylon Jet-Brush
  • Wire Brush
  • Metal Bladed Cleaners

Tube Plugs

  • Fiber
  • Brass
  • Rubber
  • Steel
  • High Pressure
  • and more...

Inspection Equipment

  • 3-Ball Micrometers
  • Rigid Video Borescope
  • Fiber-optic Video Borescope
Additional Products and Services
CTI’s tube inspection process insures the Shields and Liners are accurately sized to maintain the heat exchanger’s design flow-rate and thermal transfer efficiency.
 

Ready to Work with Us? Contact Us Today! 203-795-0070